Two JUMBO FireWALLS were tested in accordance with SANS 10177-2 at FIRELAB for 60 minute and 120 minute fire resistance and both systems met the test standard requirements.

The Insulation is an optional item and was not used in the actual test. Including Insulation into the wall cavity will improve performance during the fire, as well as give the added benefits of acoustics and thermal insulation.

The validity of the test is 5 years so valid up to August 2024.

As always with fire rated systems, installation needs to be strictly in accordance with the relevant test reports, and approved system details and specifications. If not, the fire resistance could be compromised and the test result cannot be applied.